- Product name
- Facadeshield FR
- Product code
- FR-Class B
Facadeshield FR Class B is a vapour-permeable membrane with a monolithic construction, designed for use as a breather membrane in external wall systems. It allows the passage of water vapour while providing reliable resistance to external moisture in accordance with relevant industry standards. The monolithic structure supports long-term durability, maintaining water holdout performance even after extended UV exposure. The membrane achieves a Class B reaction to fire in accordance with EN 13501-1 and is supplied in roll format for ease of handling and installation.
Facadeshield FR Class B should be incorporated within a designed construction system and installed in line with project specifications and good practice guidance.
Vapour permeable membrane for façade and external wall build-ups
Classified to Euroclass B-s1,d0 for reaction to fire
Tested to W1 water resistance under BS EN 13859-2
Maintains performance after 5000h UV exposure
Compatible with multiple sheathing board types
Recommended tapes available for installation
Technical support and toolbox talks available
Applications
External wall and façade systems requiring fire safety, water resistance, and UV stability
Performance
Euroclass B-s1,d0 fire rating
W1 water resistance
Tested to 5000h UV exposure
Installation
Can be installed with a range of sheathing board substrates including Proctor A1 Cement Board
Technical support
Expert technical support and toolbox talks available
Property |
Tset/Standard |
Result |
|---|---|---|
Total Weight |
EN1849-2 |
148 g/m2 |
Tensile Strength (MD) |
EN12311-1 |
270N/50mm |
Tensile Strength (CD) |
EN12311-1 |
225N/50mm |
Elongation (MD) |
EN12311-1 |
50% |
Elongation (CD) |
EN12311-1 |
70% |
Nail Tear Resistance (MD) |
EN12310-1 |
180N |
Nail Tear Resistance (CD) |
EN12310-1 |
220N |
Sd-value |
N12572 |
0.08m |
Watertightness |
EN 1928 |
W1 |
Resistance to Penetration of Air |
EN12114 |
0.000m3/(h*m2*50Pa) |
Fire Performance |
EN13501-1 |
B-s1,d0 |