- Product name
- Oldroyd Xtf
- Product code
- FM1
- FMA1
- FMA2
- FMA3
- Product
- Waterproofing system
- Material
- Polypropylene
- Suitability
- Tunnels
- Thickness (mm)
- 1.6mm
- Roll dimensions (w x l)
- 1.48 x 10m
Oldroyd® Xtf is a waterproof, fire-resistant membrane designed to protect tunnels from the damaging effects of dripping water.
It consists of a profiled, studded and grooved flame-retardant polypropylene (PP) sheet, approximately 1mm thick, onto which is laminated a high tensile strength, fire-resistant woven fabric of basaltic mineral fibres.
The polyolefin sheet provides the structure of the membrane and ensures its waterproofness. The basaltic fibre fabric increases its mechanical strength and protects the membrane against fire.
Oldroyd tunnel membranes
Norwegian manufacturer Oldroyd is a leading supplier of membrane systems for tunnels in Scandinavia. Newton Waterproofing is the sole UK distributor for Oldroyd Xtf membrane, a unique fireproof and waterproof product for underground projects.
Key benefits
B-s2.d0 fire rating to EN 13501-1:2007+A1:2009
Fire resistant for more than 20 minutes at >1000°C
Fixing average of 413 N to withstand the extreme negative pressure/suction of high-speed trains
Protection of the railway tunnel for a minimum of 60 years
Does not require covering, and so the whole of the overnight rail closure can be used for membrane fixing
Thoroughly tested in challenging Norwegian and Faroe Island railway tunnels
Toxic gas emissions during a fire are less than 10% of the maximum allowed level
CO2 formation is less than 20% of the maximum allowed level
Halogen free – No chlorine compounds, bromides or fluorides
Typical applications
Tunnel membrane as part of the Newton CDM System.
Suitable substrates
Bare rock surface
Cast concrete walls
Vaults in escape routes
Technical rooms (or similar)
Product data
Code: FM1
Roll size: 1.48 x 10m
Colour: Black
Packaged weight: 30kg
Area: 15/m²
Code: FMA1
Mounting kit including polypropylene fixing plugs with gaskets, stainless steel screws and covers x200
Code: FMA2
M-fix flame-retardant screws x200 (for membrane laps)
Code: FMA3
Fire-rated foam x750ml
Technical data
Properties |
Standard |
Unit |
Typical Value |
Thickness (approx.) |
mm |
~ 1,6 |
|
Height Total |
mm |
~ 8 |
|
Width |
m |
1,20 / 1,50 |
|
Length, Sheet |
m |
2,40 – 3,00 |
|
Length, Roll |
m |
5 – 20 |
|
Weight |
kg/m² |
1,6 – 2,0 |
|
Tensile Strength, Fibres |
MPa |
1300 |
|
Tensile Strength, Membrane |
MPa |
> 1000 |
|
Softening Temperatures, Fibres |
DIN 51730 |
°C |
> 1100 |
Heat Deflection Temp., Polyolefin |
ISO 75 (B) |
°C |
>120 |
Moisture Content |
ISO 3344 |
% |
<0,2 |
UL-Classification, Polyolefine |
UL 94 |
1.6 mm |
V0 |
Properties |
Standard |
Unit |
Typical Value |
Fire Test, Classification |
EN 13509 |
B-s2.d0 |
Passed |
Fire Test SBI 1 |
|||
– FIGRA0.2MJ |
EN 13823 |
W/s |
<80 |
– THR600s |
EN 13823 |
MJ |
<1 |
– SMOGRA |
EN 13823 |
m²/S² |
<50 |