- Product name
- Wraptite® UV
- Applications
- Walls
- Frame type
- Timber / wood
- Features
- UV stabilised
- Roll dimensions
- 1.5 x 50m
Wraptite® UV is a Class B fire-rated membrane that combines the best properties of vapour permeability and air tightness in one innovative, self-adhering product, specifically designed for use behind open-jointed cladding.
Wraptite UV has exceptional water resistance and UV resistance to provide a 'shadow' appearance within open rainscreen façades.
Manufactured from polyester and a functional coating, with a proprietary acrylic moisture vapour-permeable adhesive and silicone-coated PET release liner.
Key features
Airtight yet vapour-permeable
No primer required
Tough facer laminate resists punctures and tears during construction
Lightweight and easy to install
Manufactured rolled goods ensure consistent properties and performance
Wide service temperature range
Specifications
Nominal thickness: 0.38mm
Roll size: 1.5 x 50m
Material: 3-layer polypropylene micro-porous film laminate with UV-resistant coating; backed with a proprietary acrylic moisture vapour permeable adhesive and silicone-coated PET release liner
Technical properties
Base weight to be no less than 392g/m²
Water vapour permeability: to be no greater than Sd = 0.06m when tested to EN 12572 Method C
Resistance to penetration of air: to be no more than 0.01m³/m².h.50Pa when tested to EN 12114
Reaction to fire: Class B-s2,d0 when tested over 12mm calcium silicate board as per BS EN 13238:2010
UV resistance: to be no less than 12 months uncovered, with 5000hr ageing
Water penetration: to be no less than Class W1, aged and unaged, when tested to EN 1928 Method A
Tensile strength: to be no less than MD 490N; CD 330 N when tested to EN 12311-1
Tear resistance: to be no less than MD 327 N; CD 453 N when tested to EN 12310-1
Dimensional stability: to be no more than MD -0.032%; CD -0.15% when tested to EN 1107-2
Installation temperature: -10°C to +60°C
Service temperature: -40°C to +100°C
The joint openings in the façade covering to be less than 40% of the area, and maximum 50mm wide