Material Aerated concrete
Construction method Traditional
Features Lightweight
Applications External walls
Internal walls
Block dimensions (l x w x t) 215 x 65 x 100/115/140mm
Block weight (kg) 1.2
Compressive strength (N/mm2) 3.6, 7.3, 8.7
Fire rating Class O; A1
Sound reduction 49dB
Thermal conductivity (W/mK) 0.11 W/mK to 0.18 W/mK
 
 
 

Celcon Coursing Units are produced from the same material, and are suitable for all the same applications, as conventional-sized Celcon blocks, allowing consistency within the building fabric.

They are suitable for use both externally and internally in load bearing and non-load bearing situations. Note that load-bearing walls should not be constructed from coursing units as the only masonry unit.

Coursing Units are available in three compressive strengths: 2.9N/mm2 (Standard), 7.3N/mm2 (High Strength) and 8.7N/mm2 (Super Strength).

The units are fire resistant (100mm walls, up to 2 hours if load bearing, up to 4 hours if not Class [O/A1] surface spread of flame), achieving Part E of the Building Regulations, both (PCT and Robust Details).

Length 215mm
Height 65mm
Thicknesses 100-150mm.

Thermal conductivity is between 0.11 and 0.18W/mK.


Celcon Coursing Units are produced from the same material, and are suitable for all the same applications, as conventional-sized Celcon blocks, allowing consistency within the building fabric.

They are suitable for use both externally and internally in load bearing and non-load bearing situations. Note that load-bearing walls should not be constructed from coursing units as the only masonry unit.

Coursing Units are available in three compressive strengths: 2.9N/mm2 (Standard), 7.3N/mm2 (High Strength) and 8.7N/mm2 (Super Strength).

The units are fire resistant (100mm walls, up to 2 hours if load bearing, up to 4 hours if not Class [O/A1] surface spread of flame), achieving Part E of the Building Regulations, both (PCT and Robust Details).

Length 215mm
Height 65mm
Thicknesses 100-150mm.

Thermal conductivity is between 0.11 and 0.18W/mK.


Interested in this product?
Call 01732 996444
OR
 
 
 
Downloads
 
 
 
Enquire
 


Related entries

  • H+H UK: I-House system combines flexibility with tradition
    I-House system combines flexibility with tradition
    H+H UK
    The innovative I-House off-site system from H+H and SIG Off-Site gives a huge amount of flexibility to builds - any design alterations required can be easily done on site. The award-winning system was successfully trialled...
  • H+H UK: Celcon Standard Grade Blocks for floors and walls
    Celcon Standard Grade Blocks for floors and walls
    H+H UK
    Celcon Standard Grade aircrete is extremely versatile and can be used below DPC as infill for beam and block flooring systems, as well as above the ground in the walling applications listed. Celcon Standard Grade blocks are...
  • H+H UK: Celcon Solar Grade blocks for walls
    Celcon Solar Grade blocks for walls
    H+H UK
    Celcon Solar Grade blocks for walls are principally used where enhanced thermal performance is required. With a superior thermal conductivity Solar Grade blocks are suitably load-bearing for 2-storey buildings and can be...
  • H+H UK: Celcon Higher Strength Grade Blocks
    Celcon Higher Strength Grade Blocks
    H+H UK
    Celcon Higher Strength Grade aircrete is used principally where higher compressive strengths are required, such as foundations and lower storeys of three storey buildings, piers, under high vertical loads and multi-storey...
  • H+H UK: Elme Hall Hotel, Cambridge: acoustically sound extension
    Elme Hall Hotel, Cambridge: acoustically sound extension
    H+H UK
    This project entailed the demolition of existing outbuildings of the Elme Hall Hotel, followed by construction of a 34-bedroom building known as The Lodge. This extension has been built to cater for extra demand at the...
  • H+H UK: Thin-joint blocks for Code level 6 homes, Basingstoke
    Thin-joint blocks for Code level 6 homes, Basingstoke
    H+H UK
    Miller Homes decided to take real customers, as well as its supply chain, on a journey towards Code level 6 on the 3.65 acre site. The company has built five identical Miller Zero houses to different levels of the Code for...
Not found what you're looking for? View other options

Ask H+H UK about

Celcon Coursing Units